Simulate the pulse interference caused by lightning coupling, or the start stop of high-power equipment, power supply failure, etc., and test the abil
ES-516A Lightning Surge Generator is designed to simulate high-energy transient disturbances caused by lightning strikes, switching operations, and power network disturbances. It is widely used for EMC surge immunity testing of electrical and electronic equipment.
The system supports AC 0–220 V / 16 A and DC 0–110 V / 16 A EUT testing, providing adjustable surge voltage up to 6 kV and surge current up to 3 kA. It supports direct output, common-mode, and differential-mode coupling methods to meet different test requirements.
·DUT capacity range: AC 0‑220 V/16 A, DC 0‑110 V/16 A
·Surge interference voltage range: 0.2 kV‑6 kV
·Smooth waveform without burrs
·Excellent equipment stability and long‑term durability
·Automatic switching of coupling paths
·Precise phase output of surge voltage
·Automatic report storage with optional templates
·DUT damage alarm supported after surge impact
·Electronic‑switch technology adopted for long service life
·Real‑time waveform display on screen for each surge shot (optional)
| Parameter | Specification |
| Simulation Item | Surge Immunity Test |
| EUT Power Capacity | AC: 0–220 V / 16 A; DC: 0–110 V / 16 A |
| Surge Voltage | 0.2 kV–6 kV |
| Surge Current | ≤3 kA |
| Step Voltage | Freely configurable from 0.1 kV to 2 kV |
| Output Voltage Polarity | Positive, Negative, Positive-then-Negative, Negative-then-Positive |
| Open-circuit Voltage Waveform | Front time: 1.2 μs; Pulse width: 50 μs |
| Short-circuit Current Waveform | Front time: 8 μs; Pulse width: 20 μs |
| Impedance | 2 Ω, 12 Ω |
| Coupling Mode | Direct Output, Common Mode, Differential Mode |
| Coupling Capacitance | Differential Mode: 18 μF; Common Mode: 9 μF |
| Decoupling Inductance | 1.3 mH |
| Pulse Interval Time | 10 s–999 s Adjustable (depending on surge voltage range) |
| Injection Angle | 0–359°, Resolution: 1° |
| Standard Phase Angle | 0°, 90°, 180°, 270° |
| IEC Standard | Built-in IEC standards; load and perform tests according to IEC or GB/T requirements |
| Pulse Count | 1–99999 |
| Network Switching | Automatic switching |
| Operating System | Android |
| Display | 10.1-inch Intelligent Capacitive Touch Screen |
| Interfaces | HDMI, USB, RS485, LAN |
| Operating Environment | Temperature: 10℃–40℃; Humidity: 30%–70% |
| Power Supply | AC 110 V / 220 V @ 50 Hz / 60 Hz |
| Dimensions | 4U / 19" Standard Cabinet |
| Weight | 14 kg |
Friendship link: EMC testing equipment | privacy-policy.html |