Precautions for EMC Grounding Design

Release time:2026-08-27 16:22

接地是最有效的抑制骚扰源的方法,可解决50%的EMC问题。系统基准地与大地相连,可抑制电磁骚扰。外壳金属件直接接大地,还可以提供静电电荷的泄漏通路,防止静电积累。

在地线设计中应注意以下几点:

(1)正确选择单点接地与多点接地

在低频电路中,信号的工作频率小于1MHz,它的布线和器件间的电感影响较小,而接地电路形成的环流对干扰影响较大,因而应采用单点接地。当信号工作频率大于10MHz时,地线阻抗变得很大,此时应尽量降低地线阻抗,应采用就近多点接地。当工作频率在1~10MHz时,如果采用一点接地,其地线长度不应超过波长的1/20,否则应采用多点接地法。

(2)将数字电路与模拟电路分开

电路板上既有高速逻辑电路,又有线性电路,应使它们尽量分开,而两者的地线不要相混,分别与电源端地线相连。要尽量加大线性电路的接地面积。

(3)尽量加粗接地线

若接地线很细,接地电位则随电流的变化而变化,致使电子设备的定时信号电平不稳,抗噪声性能变坏。因此应将接地线尽量加粗,使它能通过三位于印制电路板的允许电流。如有可能,接地线的宽度应大于3mm。

(4)将接地线构成闭环路

设计只由数字电路组成的印制电路板的地线系统时,将接地线做成闭环路可以明显的提高抗噪声能力。其原因在于:印制电路板上有很多集成电路组件,尤其遇有耗电多的组件时,因受接地线粗细的限制,会在地结上产生较大的电位差,引起抗噪声能力下降,若将接地结构成环路,则会缩小电位差值,提高电子设备的抗噪声能力。

RCETEST is a hightech enterprise focusing on electromagnetic compatibility (EMC) testing including independent R&D, manufacturing, sales and fulllifecycle supporting services, and provides professional EMC test instruments and systematic turnkey testing solutions for global customers.
Civilian field: Electrostatic discharge generator, EFT/Burst generator, lightning surge generator, radio frequency conduction anti-interference test system, industrial frequency magnetic field generator, damping oscillation magnetic field generator, alternating voltage drop generator, etc.
Automotive field: Electrostatic discharge generator, 7637 test system, automotive low-voltage electrical performance test system, automotive high-voltage electrical performance test system, high current injection test system, automotive low-frequency magnetic field immunity, radio frequency radiation immunity test system, etc.
Military field: Electrostatic discharge generator, low-frequency conduction immunity test system, onboard power supply characteristics, cable bundle injection test system, low-frequency magnetic field immunity test system, high-speed damping oscillation test system, etc.


Previous: What are the differences between a shielding room and a darkroom?   Next: Common Electromagnetic Compatibility (EMC) Issues and Solutions
  • Phone:8615399916585
  • Changsha headquarters:Luzhu Enterprise Plaza, Building B1, 6th Floor, Yueliu District, Changsha City, Hunan Province
  • Shenzhen Service Point: Room 613, Building 2, Jiufang Plaza, Tiezai Road, Gongle Community, Xixiang Street, Bao'an District, Shenzhen
  • Shanghai Service Point: Room 4-2B, 4th Floor, Building 3, No. 516 Huachuan Road, Baoshan District, Shanghai
  • Chengdu Service Point: Room 2207, T2 Office Building, Xiangnian Plaza, No. 88 Jitai 5th Road, Wuhou District, Chengdu City

Friendship link: EMC testing equipment | privacy-policy.html |

Welcome to Changsha Rongce Electronic Co., Ltd.
Welcome to Changsha Rongce Electronic Co., Ltd.
Please leave your message, we will reply to you as soon as possible
  • *
  • *
  • *
  • *